- Kneader series
- Grinding and Dispersing series
- Mixing and kneading series
- Pressure Vessel Series
- Dry powder mixer series
- High viscosity mixing series
- Stirring and dispersing series
- Emulsifying homogeneous series
- Grinding series
- Filter series
- Large storage and pressure vessel series
- Boiler&Heat-conducting oil furnace series-4
- Centrifuge machine
- Chemical plant production line
- Mine Car & Wheel Set
- Mine Locomotive
- Mining Man Car
- Diesel Locomotives
- Muck Shovel Loader
- Mucking Machine
- Rock Loader
- Scraper Conveyer
- Belt Conveyor
- Air Compressor
- Ventilation Equipment
- Roadheader Machine
- Mining LHD
- Coal Shearer
- Mine Car Dumper
- Mining Electric Appliance
- Mine Communication
- Gas Drainage Pumping Station
- Rail Catcher
- UNI-T UTi165K Infrared Thermal Imaging Camera Digital Imagining Camera
- UNI-T UTi85H+ Infrared Thermal Imaging Digital Camera
- Dynamic Face Recognition and Thermometry Terminal
- Non-Contact Infrared Thermometer
- Face recognition body temperature detector
- Non Contact Infrared Thermometer
- Body temperature scanner with disinfection machine in public place
- Face recognition temperature measurement and disinfection machine
- Steel Rail
- Track Switch
- Rail Transit Equipment
- Rail Transit Equipment
- Rail Arrester
- Seamless Steel Pipe
- Railway Parts
- Railway Sleepers
- Mining Steel
- Steel Shot
- Steel Plate & Steel Sheet
- U Channel Steel Support
- Hydraulic Acrow Props
- Hydraulic Roof Supports
- Hinged Bar
- Anchor Bolt
- Anchor Agent
- Mining Lamp
- Mining Lamp Battery Charger
- Self Rescuer
- Oxygen Filling Pump
- Air Breathing Respirator SCBA
- Protection Equipment
- Mobile Gas Drainage Pumping
- Medical Protection
- Guniting Equipment
- Wall Rendering Machine
- Construction Mixer
- Mobile Concrete Mixer Truck
- Road Roller Compactor
- Road Construction Machine
- Excavator
- tipper truck, dump truck, mining truck
- Pile Driver
- Light Tower
- Athletic Field Equipment
- Concrete Saw Cutter
- Rebar Tying Machine
- Rebar Cutter and Bender
- Shipping Container
- Pavement Repair Vehicle
- Hydraulic Power Station
Chemical Equipment
Mining Equipment
Human Infrared Thermal Imaging
Thermometer
Robot
Railway Equipment & Steel Rail
Drilling Equipment
Supporting Equipment
Lifting Equipment
Safety & Protection Equipment
Construction Machine
Pump Equipment
Excavator & Bulldozer Spare Parts
Transportation Equipment
CNC Rebar Equipment
UAV
Crawler Transport Vehicle
Body temperature scanner with disinfection machine in public place
Related Products
- zyzn@zyzngf.com
- 18660761303
Payment Terms: TT, Western Union ,Paypal MOQ:Contact us to confirm
Related Products of Body temperature scanner with disinfection machine in public place
Model: TS-BS600
Application:
It is suitable for stations, hospitals, schools, banks, office buildings, army courtyards, office halls of various institutions, residential quarters, large factories, and vegetable markets.
Temperature measuring door post disinfection machine uses high-precision infrared temperature sensor, the sensing distance is 0-15cm,With high precision and high resolution, immune,small interference, measurement error ± 0.1℃at room temperature.The initial temperature setting is 37.3 ° C (adjustable). When the detection door is working, it will display an alarm when the detected actual body temperature exceeds 37.3 ° C. After the pedestrian measures the temperature, they can reach into the sterilizer and drop the disposable disinfectant solution automatically after sensing, so as to achieve the disinfection effect and prevent the virus in their hands from being constantly transmitted.
Working temperature: 5℃~ 40℃Temperature Measurement range: 32℃~ 42.9℃Temperature Measurement error: ± 0.1℃
Relative humidity: ≤85%
Pass rate: 1 second per person (average data) Working voltage: DC12V,
Working current: 5mA
Working power: AC110-220V, 50 / 60HZ
Disinfection solution: 1L as standard, 1000 persons / time Power:﹤20W Net weight: 30KG
Dimensions: 1850mm (height) x 150mm (width) x 330mm (depth) Material: 304 stainless steel
Waterproof rating: IP55
3.Product function diagram introduction and temperature measurement alarm prompt:
Product size
1. Device installation
The installation of this equipment is very simple. It is recommended
to choose an environmental area where the room temperature does not exceed 30
degrees and the low temperature does not fall below -10 degrees;
After selecting
the installation area of the device, fix the device
at the bottom and plug it in and use it. Note: Please choose a level ground to
install the equipment to prevent the equipment from tilting; the bottom must be
fixed firmly to avoid falling down.
1. Power on: Plug in the power supply (this product is powered by AC 220V),
touch the power button
on the monitor for about 6 seconds, and after you hear the "Didi
Didi" four beeps, the display is completed.
2. Start the temperature measurement: When the device
is turned on, or the device is in the standby
state, you need to start the temperature measurement. You only need to use the hand or forehead to irradiate the
temperature in the temperature measurement area. When you hear a
"drop", the display turns on. The temperature measurement function
has been started.
3.
Detection: Pedestrians enter the
detection range and bring their foreheads close to the detection area (5-20CM).
When they hear a "drop" from the device, the detection is completed
and takes 1-2 seconds; the detection results will appear immediately On the display.
4. Disinfection:
This equipment is equipped with an automatic induction disinfection machine.
When the pedestrian detection result is normal body temperature, the pedestrian
puts his hand under the automatic induction disinfection machine, the hands
from bottom to top, the automatic induction disinfection machine drips the
disinfection solution, and the pedestrian You
can leave after rubbing your hands.
5. Standby: When the device does not perform temperature measurement for more than 60 seconds,
the display of the device will go out, and the device's temperature measurement
function will enter the standby state.
1. Do not measure
for a while or immediately after breastfeeding
2. Do not use in a
temperatureless environment
3. Do not drink, eat
or exercise before or during the measurement
4. If
there is dust, hair or sweat on the temperature measuring probe, please wipe it
with alcohol or disinfectant immediately
5. Don't
leave the temperature measurement area when you don't hear the "drop"
sound at the end of the measurement
6. Please try to
measure in the specified measurement area
Dear
Customer: Hello!
Thank you for patronizing our products! To protect your
rights and interests, please read the contents carefully after purchasing:
(1) The
following conditions are not within the scope of free maintenance. We can
provide paid services. Please note:
1. Product damage
caused by failure to install or use according to the instruction manual
2. The product
exceeds the warranty period
3. The use of
non-our company's accessories caused damage to the machine
4. The product
has been disassembled or repaired by personnel not authorized
by our company
5. Product damage
caused by unexpected factors or human
behavior, such as mechanical damage, drop, severe oxidation of the
product, etc.
6.Damage caused by
transportation, loading and unloading during customer's return
7. Product damage
caused by other irresistible natural forces such as earthquakes, fires, etc.
8. Failure or damage caused by other issues than the design,
technology, manufacturing, quality, etc. of the product itself
(2) , special instructions
1. If
there is obvious man-made hard object damage, cracks, severe deformation, etc.,
it will not be replaced. Users can purchase it
separately.
2. The warranty
replacement is limited
to the core parts, and the accessories such as packaging
and various technical materials are not covered by the warranty
replacement. If the equipment performance problem occurs within 15 days after
the product is purchased, and the appearance is not scratched, you can directly
replace the new product. Warranty replacement products must be tested by our company. If it is a good opportunity, it
will be returned directly to the customer. If the fault is confirmed, the same
model product will be replaced, and the defective spare parts replaced will
belong to our company.
(3) These regulations
shall become effective on the date of promulgation.
(4) This product is
guaranteed for one year from the date of sale and shipment
Star Rating: |